Design
Submersible sewage pump for continuous duty for stationary and portable wet well installation, as well as for stationary dry well installation.
Application
Pumping of
- Untreated sewage
- Sewage containing faeces
- Wastewater
Equipment/function
- Leakage detection for the motor compartment
- Winding temperature monitoring with bimetallic strip
- Optional external pencil electrode for sealing chamber control
- Single-phase version with capacitor switchgear
Typekey
Example: | Wilo-Rexa PRO V06DA-110/EAD1X2-T0015-540-O |
PRO | Series name |
V | Type of impeller:
V = vortex impeller C = single-channel impeller |
06 | Nominal diameter of pressure connection e.g. DN 65 |
D | Hydraulic version:
D = suction side drilled acc. to DIN N = suction side drilled acc. to ANSI (American National Standards Institute) |
A | Material version, hydraulics |
110 | Hydraulics definition |
E | Surface-cooled motor |
A | Material version, motor |
D | Seal with two independent mechanical seals |
1 | IE efficiency class, e.g. 1 = IE1 (derived from IEC 60034-30) |
X | Ex rating:
X = ATEX F = FM C = CSA |
2 | Number of poles |
T | Mains connection version:
M = 1~ T = 3~ |
0015 | Value/10 = rated power P2 in kW |
5 | Frequency (5 = 50 Hz, 6 = 60 Hz) |
40 | Rated voltage code |
O | Additional electrical equipment:
O = with bare cable end F = float switch with bare cable end A = float switch with plug P = with plug |
Technical data
- Mains connection: 1~230 V, 50 Hz or 3~400 V, 50 Hz
- Submerged operating mode: S1
- Non-immersed operating mode: S2-30 min; S3 25%
- Protection class: IP68
- Insulation class: F, optionally H
- Fluid temperature: 3…40 °C, max. 60 °C for 3 min
- Max. immersion depth: 20 m
- Cable length: 10 m
Materials
- Motor housing: EN-GJL-250
- Hydraulics housing: EN-GJL 250
- Impeller: EN-GJL 250 or EN-GJS-500-7
- Static gaskets: NBR
- Sealing on pump side: SiC/SiC
- Sealing on motor side: C/MgSiO4
- Shaft end: Stainless steel 1.4021
Construction
Submersible sewage pump as submersible monobloc unit for stationary and portable wet well installation, as well as stationary dry well installation.
Hydraulics
The outlet on the pressure side is designed as horizontal flange connection. The maximum possible dry matter is 8 % (depending on the hydraulics). Vortex and single-channel impellers are used.
Motor
The motor versions used are single-phase current and three-phase current surface-cooled motors. For single-phase current motors, the condenser is installed in a separate switchgear. Depending on performance, activation is carried out via direct startup or star/delta startup.
The motor is cooled by the medium around it (pumped fluid or air). The waste heat is dissipated via the motor housing.
The motors can be immersed during continuous duty (S1). In submerged operation, the operating modes S1 (continuous duty), S2 (short-time duty) or S3 (intermittent) are possible depending on the rated motor power.
Furthermore the motors are equipped with the following monitoring devices:
- Leakage detection motor compartment: The leakage detection signals water ingress into the motor compartment.
- Thermal motor monitoring: thermal motor monitoring protects the motor winding against overheating. Bimetallic strips are used for this as standard.
The motor can also be fitted with an external sealing chamber electrode to monitor the sealing chamber. This signals if there is water ingress into the sealing chamber through the mechanical seal on the fluid side.
The connection cable has bare cable ends and a length of 10 m as standard, and is available in following versions:
Seal
Located between the motor and hydraulics is a sealing chamber with the seal on the fluid and motor side. This sealing chamber is filled with medicinal white oil. The fluid-side and motor-side seals are provided by two mechanical seals which rotate independently of each other.
Delivery state
- Submersible sewage pump with 10 m cable
- Operating and maintenance manual