<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Fire Pump Archives - MARINE</title>
	<atom:link href="https://marineqatar.com/product-category/fire-pump/feed/" rel="self" type="application/rss+xml" />
	<link>https://marineqatar.com/product-category/fire-pump/</link>
	<description>TRADING &#38; CONTRACTING</description>
	<lastBuildDate>Thu, 04 Jun 2026 08:50:34 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0</generator>

<image>
	<url>https://marineqatar.com/wp-content/uploads/2021/10/cropped-site-icon-32x32.png</url>
	<title>Fire Pump Archives - MARINE</title>
	<link>https://marineqatar.com/product-category/fire-pump/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Wilo FireSet</title>
		<link>https://marineqatar.com/product/wilo-fireset/</link>
		
		<dc:creator><![CDATA[MarineAdmin22]]></dc:creator>
		<pubDate>Thu, 04 Jun 2026 08:50:33 +0000</pubDate>
				<guid isPermaLink="false">https://marineqatar.com/?post_type=product&#038;p=15123</guid>

					<description><![CDATA[<p>Wilo-FireSet is a configurable fire-fighting pressure boosting system designed for automatic sprinkler-based fire protection applications. The system offers maximum flexibility through modular components and can be configured according to international fire protection standards such as NFPA 20, EN 12845, UL, VdS, and CNPP. Built with robust Wilo fire pumps, advanced controllers, and reliable drive options, [&#8230;]</p>
<p>The post <a href="https://marineqatar.com/product/wilo-fireset/">Wilo FireSet</a> appeared first on <a href="https://marineqatar.com">MARINE</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>Wilo-FireSet is a configurable fire-fighting pressure boosting system designed for automatic sprinkler-based fire protection applications. The system offers maximum flexibility through modular components and can be configured according to international fire protection standards such as NFPA 20, EN 12845, UL, VdS, and CNPP. Built with robust Wilo fire pumps, advanced controllers, and reliable drive options, Wilo-FireSet ensures dependable operation in critical fire protection systems.</p>
<p><strong>Your Advantages</strong></p>
<ul>
<li>Flexible configuration for a wide range of fire-fighting applications.</li>
<li>Complies with international fire protection standards including NFPA 20 and EN 12845.</li>
<li>Available with UL, VdS, and CNPP certified components.</li>
<li>Modular design allows customized system solutions and easy maintenance.</li>
<li>High-performance Wilo pumps with split-case or back pull-out construction.</li>
<li>Compact base-frame design simplifies transportation and installation.</li>
<li>Optional LCD controller with user-friendly operation and fault diagnostics.</li>
<li>Available with electric or diesel-driven pump configurations.</li>
</ul>
<p><strong>Design</strong></p>
<p>Pressure boosting system for fire-fighting applications consisting of:</p>
<ul>
<li>One main fire pump mounted on a horizontal base frame.</li>
<li>Split-case or back pull-out pump construction.</li>
<li>Electric motor or diesel engine drive.</li>
<li>Spacer coupling or universal joint coupling.</li>
<li>Dedicated fire pump controller/switchgear.</li>
<li>Pressure sensing and automatic pump start functionality.</li>
</ul>
<p><strong>Application</strong></p>
<p>Suitable for automatic water supply to sprinkler fire protection systems in:</p>
<ul>
<li>Commercial Buildings</li>
<li>Residential Complexes</li>
<li>Hotels</li>
<li>Hospitals</li>
<li>Shopping Malls</li>
<li>Office Buildings</li>
<li>Industrial Facilities</li>
<li>Public Buildings</li>
</ul>
<p><strong>Equipment / Function</strong></p>
<p><strong>Standard Features</strong></p>
<ul>
<li>Main fire pump with electric or diesel drive.</li>
<li>Robust steel base frame with lifting points.</li>
<li>Fire pump controller/switchgear.</li>
<li>Dual pressure sensors for automatic operation.</li>
<li>Flexible coupling arrangement.</li>
<li>Factory-tested and ready-to-connect package.</li>
</ul>
<p><strong>Diesel Engine Models</strong></p>
<ul>
<li>Water-to-water heat exchanger cooling system.</li>
<li>Fuel tank with 6 to 8 hours operating autonomy.</li>
<li>Dual battery sets with battery charger.</li>
<li>Optional direct air cooling system.</li>
</ul>
<p><strong>Optional Accessories</strong></p>
<ul>
<li>Jockey Pump</li>
<li>Jockey Pump Controller</li>
<li>Flow Meter</li>
<li>Eccentric Suction Cone Kit</li>
<li>Concentric Discharge Cone Kit</li>
<li>Flexible Vibration Dampers</li>
<li>Battery Density Meter</li>
<li>Diesel Engine Spare Parts Kit</li>
<li>Low Noise Silencer (30 dBA)</li>
<li>Pressure Relief Valve (FM Approved)</li>
<li>Circulation &amp; Relief Valve (FM Approved)</li>
</ul>
<h2 style="text-align: center;">Technical Data</h2>
<table width="50%">
<tbody>
<tr>
<th>Description</th>
<th>Value</th>
</tr>
<tr>
<td>Fluid Type</td>
<td>Clean, Non-Aggressive Water</td>
</tr>
<tr>
<td>Power Supply</td>
<td>3~400V, 50Hz</td>
</tr>
<tr>
<td>Maximum Flow Rate</td>
<td>Up to 750 m³/h</td>
</tr>
<tr>
<td>Maximum Head</td>
<td>Up to 128 m</td>
</tr>
<tr>
<td>Maximum Operating Pressure</td>
<td>16 – 25 bar</td>
</tr>
<tr>
<td>Maximum Water Temperature</td>
<td>+25°C</td>
</tr>
<tr>
<td>NFPA Version Water Temperature</td>
<td>+30°C</td>
</tr>
<tr>
<td>Electric Motor Power</td>
<td>Up to 315 kW</td>
</tr>
<tr>
<td>Diesel Engine Power</td>
<td>Up to 336 kW</td>
</tr>
<tr>
<td>Motor Speed</td>
<td>1480 / 2980 rpm</td>
</tr>
<tr>
<td>Motor Protection Class</td>
<td>IP55</td>
</tr>
<tr>
<td>Controller Protection Class</td>
<td>IP54</td>
</tr>
<tr>
<td>Suction Connection Size</td>
<td>DN 50 – DN 200</td>
</tr>
<tr>
<td>Discharge Connection Size</td>
<td>DN 32 – DN 200</td>
</tr>
<tr>
<td>Electric Installation Altitude</td>
<td>Up to 1000 m</td>
</tr>
<tr>
<td>Diesel Installation Altitude</td>
<td>Up to 91 m</td>
</tr>
</tbody>
</table>
<h2 style="text-align: center;">Materials</h2>
<h4>Split-Case Pump</h4>
<table>
<tbody>
<tr>
<th>Component</th>
<th>Material</th>
</tr>
<tr>
<td>Impeller</td>
<td>Bronze CuSn10</td>
</tr>
<tr>
<td>Pump Casing</td>
<td>Cast Iron GG30</td>
</tr>
<tr>
<td>Shaft</td>
<td>Stainless Steel AISI 410</td>
</tr>
<tr>
<td>Shaft Sleeve</td>
<td>Stainless Steel AISI 410</td>
</tr>
<tr>
<td>Wear Rings</td>
<td>Bronze</td>
</tr>
</tbody>
</table>
<h4>Back Pull-Out Pump</h4>
<table>
<tbody>
<tr>
<th>Component</th>
<th>Material</th>
</tr>
<tr>
<td>Impeller</td>
<td>Bronze CuSn10 / CuAl10Fe5Ni5</td>
</tr>
<tr>
<td>Neck Ring</td>
<td>Stainless Steel AISI 316L</td>
</tr>
<tr>
<td>Pump Casing</td>
<td>Cast Iron EN-GJL-250</td>
</tr>
<tr>
<td>Shaft</td>
<td>Stainless Steel AISI 420</td>
</tr>
</tbody>
</table>
<h4>Jockey Pump</h4>
<table>
<tbody>
<tr>
<th>Component</th>
<th>Material</th>
</tr>
<tr>
<td>Impeller</td>
<td>Stainless Steel AISI 304</td>
</tr>
<tr>
<td>Pump Casing</td>
<td>Stainless Steel AISI 304</td>
</tr>
<tr>
<td>Shaft</td>
<td>Stainless Steel AISI 304</td>
</tr>
<tr>
<td>O-Rings</td>
<td>EPDM</td>
</tr>
</tbody>
</table>
<h4>Construction</h4>
<p><strong>Base Frame</strong></p>
<p>Heavy-duty epoxy-coated steel frame with integrated lifting points. Optional galvanized construction available.</p>
<p><strong>Pump Assembly</strong></p>
<p>Horizontal fire pump with split-case or back pull-out design for simplified maintenance and service access.</p>
<p><strong>Fuel Tank</strong></p>
<p>Epoxy-coated steel fuel tank with fuel gauge, drain valve, and air vent system.</p>
<p><strong>Sensors &amp; Instrumentation</strong></p>
<p>Pressure sensors and pressure gauges ensure automatic operation and continuous monitoring.</p>
<p><strong>Control System</strong></p>
<p>Dedicated electric or diesel fire pump controller with optional LCD display and intuitive menu navigation.</p>
<hr />
<p>Delivery State</p>
<p>Factory assembled, tested, and ready for installation.</p>
<p><strong>Scope of Supply</strong></p>
<ul>
<li>Fire Pump Assembly</li>
<li>Electric Motor or Diesel Engine</li>
<li>Coupling Set</li>
<li>Base Frame</li>
<li>Fire Pump Controller</li>
<li>Pressure Sensors</li>
<li>Installation &amp; Operation Manual</li>
<li>Pump Documentation</li>
<li>Controller Documentation</li>
</ul>
<p><strong>Optional Supply</strong></p>
<ul>
<li>Jockey Pump Package</li>
<li>Flow Meter Package</li>
<li>Valve Assemblies</li>
<li>Vibration Isolators</li>
<li>Additional Fire Protection Accessories</li>
</ul>
<p>The post <a href="https://marineqatar.com/product/wilo-fireset/">Wilo FireSet</a> appeared first on <a href="https://marineqatar.com">MARINE</a>.</p>